High Power Transformer Protection Device R40 Series Transformer Gas Relay

Product Details
Theory: Electromagnetic Relay
Usage: Transformer
Phase: 1
Still deciding? Get samples of US$ 80/Piece
Request Sample
Gold Member Since 2022

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Year of Establishment
2013-03-18
Plant Area
165 square meters
  • High Power Transformer Protection Device R40 Series Transformer Gas Relay
  • High Power Transformer Protection Device R40 Series Transformer Gas Relay
  • High Power Transformer Protection Device R40 Series Transformer Gas Relay
  • High Power Transformer Protection Device R40 Series Transformer Gas Relay
  • High Power Transformer Protection Device R40 Series Transformer Gas Relay
  • High Power Transformer Protection Device R40 Series Transformer Gas Relay
Find Similar Products

Basic Info.

Electricity Type
Ac
Number of Pole
1
Load
High Power Relay
Protective Characteristics
Sealed Relay
Action Principle
Electronic Type
Type
Electric Parameter Relay
Transport Package
/
Specification
customization
Trademark
/
Origin
China
HS Code
853650009
Production Capacity
5000

Product Description

High Power Transformer Protection Device R40 Series Transformer Gas Relay
High Power Transformer Protection Device R40 Series Transformer Gas Relay
High Power Transformer Protection Device R40 Series Transformer Gas RelayHigh Power Transformer Protection Device R40 Series Transformer Gas Relay
R40 series transformer gas relay
   R40 series gas relays are mainly used to protect various types of oil-immersed fully sealed transformers. When the transformer is running, gas is generated due to internal faults, and the gas collects in the gas collecting chamber of the gas relay. When the volume of the gas reaches a certain amount, the alarm or trip contact is triggered, and an alarm signal or a trip signal is output, thereby achieving protection of the transformer. purpose.

   Scope of use: (a). Mounting position: Mounted on the top or side wall of the lid. (b). Environmental requirements: -45 ° C ~ +70 ° C; working environment: -45 ° C ~ +120 ° C; (c). Relative humidity: no more than 95% at +20 °C; (d). Degree of protection: IP55; (e). Power frequency withstand voltage: 2000V, 1min; (f). Insulation performance: 2500V, 500MΩ
 
The gas relay is internally composed of a liquid level transfer mechanism and two magnetic switches 1, 2, 3, 4 (or 1, 2, 3, 4, 5, 6), and the switch action transmits an alarm signal or a trip signal through the terminal block. Output.
 
When the transformer is in normal operation, the inside of the gas relay is filled with transformer oil. When there is a fault inside the transformer, the gas generated by the decomposition of the transformer oil collects in the gas collecting chamber of the relay. The air pressure forces the oil level to drop, and the float decreases with the oil level. When the liquid level drops to the alarm setting value (factory setting is 170ml±15ml), the interlocking magnetic switch 1, 2 (or 1, 2, 3) will give an alarm signal. When a serious fault occurs inside the transformer, a large amount of gas will be generated, and the oil level will drop rapidly. When it falls to the trip setting value (factory setting is greater than 230ml ± 15ml), the magnetic switch 3, 4 (or 4, 5, 6) is linked. The action signals a trip. The transformer is tripped from the grid to protect the transformer. (Note: The gas alarm signal volume value and the trip signal setting value can be adjusted according to the user's requirements)
High Power Transformer Protection Device R40 Series Transformer Gas RelayHigh Power Transformer Protection Device R40 Series Transformer Gas Relay
 
High Power Transformer Protection Device R40 Series Transformer Gas RelayFAQ

1.Q:What's your main products?
A: We provide professional Transformer Accessories and Insulation Materials with 15 years experience.
 
2.Q Why chooses us?
A: Well experienced in our field. Our staff of engineers offers high-valued design guidance to
assure product performance and efficiency. And our strict adherence to rigorous quality control and tolerance standards lead to easier assembly of finished components at your facility. We always focus on Quality.
 
3. Q:How can you control your quality?
A:For each production processing, we have complete QC system for the chemical composition, physical and electrical properties.After production, all the goods will be tested according to related standards, and the ex-factory test reports will be sent along with shipment documents.
 
4. Q: Does your company accept customization?
A. Yes, we can accept OEM/ODM.
 
5.Q: Do you have the products instock?
A: Depends on your request,we have standard models in stock.Some special product and big order will be newly produced according to your order.
 
6. Q: What's your payment terms?
A: We usually accept all kinds of payment terms, T/T, L/C, Western union, Cash.
 
7. Q: What do you have for certificate?
A: :Quality Service Credit Certificate, Enterprise Credit Grade Certificate,Credit Operation Demonstration Unit Certificate, Quality Management System Certificate, etc.
 
8.Q:Can we visit your company?
A:Yes,for sure, you are welcome to visit our company.
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier